Lower Display

Prompt

TIME1 (continued)

HRS.MIN1

OR

DAYS.HRS1

TIME 2

HRS.MIN2

OR

DAYS.HRS2

TIME 3

HRS.MIN3

OR

DAYS.HRS3

COUNTER1

COUNTER 1

Upper Display

Range of Setting

or Selection

GSOAK

SOOTNG

DIGIN1

DIGIN2

MAN2

00.00 to 23.59

1.00to 416.15 Same as TIME 1

00.00to 23.59

1.00to 416.15 Same as TIME 1

00.00to 23.59

1.00 to 416.15

DISABL

MANUAL

AL1SP1

AL1SP2

AL2SP1

AL2SP2

DIGIN1

DIGIN2

OUT1*1K

OUT2*1K

GSOAK

PWRCYC

PV_RNG

FAILSF

TUNE

MAN2

PVRNG2

FSF2

Parameter

Definition

GUARANTEED SOAK— Cumulative time the process was outside the guaranteed soak band.

SOOTING— Cumulative time process was in sooting state DIGITAL INPUT1— Cumulative time Digital Input 1 was closed

DIGITAL INPUT 2— Cumulative time Digital Input 2 was closed

LOOP 2 MANUAL— Cumulative time Loop 2 was in Manual.

Shows elapsed time of Timer 1 in Hours and Minutes. At 24.00, units change automatically to Days and Hours.

The timer tracks the elapsed time of the selected event.

Shows elapsed time of Timer 2 in Hours and Minutes. At 24.00, units change automatically to Days and Hours.

The timer tracks the elapsed time of the selected event.

Shows elapsed time of Timer 3 in Hours and Minutes. At 24.00, units change automatically to Days and Hours.

COUNTER 1—The counter counts the number of times the selected event has occurred.

DISABLE— Counter is not in use.

LOOP 1 MANUAL— Number of times Loop 1 has been in Manual mode.

ALARM 1 SETPOINT 1— Number of times Alarm 1 Setpoint 1 has been activated.

ALARM 1 SETPOINT 2— Number of times Alarm 1 Setpoint 2 has been activated.

ALARM 2 SETPOINT 1— Number of times Alarm 2 Setpoint 1 has been activated.

ALARM 2 SETPOINT 2— Number of times Alarm 2 Setpoint 2 has been activated.

DIGITAL INPUT 1— Number of times Digital Input 1 has closed.

DIGITAL INPUT 2— Number of times Digital Input 2 has closed.

OUTPUT 1 RELAY x 1000— Thousands of times Output 1 relay has been activated.

OUTPUT 2 RELAY x 1000— Thousands of times Output 2 relay has been activated.

GUARANTEED SOAK— Number of times unit has been in guaranteed soak.

POWER CYCLE— Number of times unit’s power has cycled off and on.

LOOP 1 PV RANGE— Number of times Loop 1’s PV has been out of range.

LOOP 1 FAILSAFE— Number of times Loop 1 has been in Failsafe mode.

LOOP 1 TUNE— Number of times Loop 1 has been tuned (manually and automatically)

LOOP 2 MANUAL— Number of times Loop 2 has been in Manual mode.

LOOP 2 PV RANGE— Number of times Loop 2’s PV has been out of range.

LOOP 2 FAILSAFE— Number of times Loop 2 has been in

4/00

UDC 3300 Process Controller Product Manual

145

Page 157
Image 157