2.2 Model Number Interpretation

Model number

The model number interpretationis shown in Figure 2-1. Write the model number into the spaces provided and compare it to the model number interpretation. This information will also be useful when you wire your controller.

Figure 2-1 Model Number Interpretation

 

 

Key Number

Table I

 

 

D C 3 3 0

 

 

 

 

 

B = Basic Controller Model

 

 

E = Expanded Controller Model

 

 

L = Limit Controller Model

 

 

D = Basic Model with UDC 3000 DMCS

 

 

Functionality

 

 

 

 

 

 

 

 

 

 

Output #1

 

 

C0 =

Current without Alarms or Output 2

 

 

K – =

Current with Alarm 1

 

 

E – =

Relay, E-M with Alarm 1

 

 

A – =

Relay, SS 1 amp with Alarm 1

 

 

S – =

Relay, SS 10 amp with Alarm 1

 

 

T – =

Open Collector Output

 

 

Output #2 or Alarm #2

 

 

0 = None

E = Relay, E-M

A = Relay, SS 1 amp

S = Relay, SS 10 amp

T = Open Collector Output

External Interface

0

– – =

None

1

– – =

RS422/485 ASCII / Modbus

2

– – =

Auxiliary Output (Loop 2 Current Output)

4

– – =

DMCS Communications

5

– – =

Auxiliary Output + RS422/485 / Modbus

Software Options

0 – = Standard Functions (includes Accutune II)

1 – = Standard Functions (includes Accutune II and HealthWatch)

A – = Setpoint Programming (SPP)— DMCS Model

B – = SPP

C – = Math Option + SPP

D – = 2 Loops/Internal Cascade + SPP

E – = Math Option + 2 Loops/Internal Cascade +

SPP

F – = Math Option + SPP + HealthWatch

G – = 2 Loops/Internal Cascade + SPP + HealthWatch

H – = Math Option + 2 Loops/Internal Cascade + SPP + HealthWatch

Digital Inputs

– 0 = None

– 3 = Two Digital Inputs

Table II

Table III

 

Table IV

 

Table V Table VI

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

Manuals

 

 

 

 

0 – =

English

 

 

 

 

F – = French

 

 

 

 

G – = German

 

 

 

 

T – =

Italian

 

 

 

 

S – = Spanish

 

 

 

 

Certificate

 

 

 

 

– 0 = None

 

 

 

 

– C = Certificate of Conformance

 

 

 

 

 

(F3391)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

0 – – – – = 90 to 264 Vac Power

 

 

 

1 – – – – = 24 Vac/dc Power

0 – – – = None

A – – – = CSA, FM, and UL

F – – – = FM and UL

– 0 – – = Gray Elastomer Bezel

– B – – = Blue Elastomer Bezel

– T – – = Tan Elastomer Bezel

– – 0 – = None

– – P – – = Rear Terminal Cover

– – T – = Customer ID Tag

– – U – = Rear Terminal Cover & Tag

– – – 0 = None

– – – D = DIN Cutout Adapter

– – – – 0= None

PV Input

1 – = T/C, RTD, Radiamatic, mV, 0-5V, 1-5V

2= T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA

3= T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA, 0-10V

1 5 = Relative Humidity (includes optional input)

1 6 = Carbon, Oxygen, or Dewpoint (includes optional input)

Optional Input(s)

0 = None

1 = T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA

2 = Slidewire Input

3 = T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA, 0-10V

4 = Two High Level AIs instead of 2nd Universal AI

24151

12

UDC 3300 Controller Product Manual

4/00

Page 24
Image 24
Honeywell UDC 3300 manual Model Number Interpretation, Model number