3.25Configuration Record Sheet

Expanded Model: DC330E-XX-XXX

Keep a record

Enter the value or selection for each prompt on this sheet so you will have a record of how your controller was configured.

Group

Prompt

TUNING

Function

Prompt

PROP BD or

GAIN or GAINVALn

RATE MIN RSET MIN or

RSET RPM MAN RSET PROPBD2 or

GAIN 2 RATE2MIN RSET2MIN or

RSET2RPM CYC SEC or

CYC SX3 CYC2 SEC or

CYC2 SX3

SECURITY LOCKOUT AUTO MAN SP SEL RUN HOLD PVEUVAL1 PVEUVAL2 PVEUVAL3 PVEUVAL4 PVEUVAL5 PVEUVAL6 PVEUVAL7 PVEUVAL8 GAINVAL1 GAINVAL2 GAINVAL3 GAINVAL4 GAINVAL5

Value or

Selection

__________

__________

Read Only

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

Factory Setting

- -

1.000

- -

0.00

1.00

- -

0

- -

1.000

0.00

1.00

- -

20

20

20

20

0

CALIB

ENABLE ENABLE ENABLE 0

0

0

0

0

0

0

0

1.000

1.000

1.000

1.000

1.000

Group

Prompt

TUNING2

Function

Prompt

PROPBD3 or

GAIN 3 or GAINVALn

RATE3MIN

RSET3MIN or

RSET3RPM

MANRSET3

PROPBD4 or

GAIN 4 RATE4MIN RSET4MIN or

RSET4RPM CYC3 SEC or

CYC3 SX3

CYC4 SEC or

CYC4 SX3

PVEUVAL1

PVEUVAL2

PVEUVAL3

PVEUVAL4

PVEUVAL5

PVEUVAL6

PVEUVAL7

PVEUVAL8

GAINVAL1

GAINVAL2

GAINVAL3

GAINVAL4

GAINVAL5

GAINVAL6

GAINVAL7

GAINVAL8

Value or

Selection

__________

__________

Read Only

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

__________

Factory Setting

- -

1.000

- -

0.00

1.00

- -

0

- -

1.000

0.00

1.0

- -

20

20

20

20

0

0

0

0

0

0

0

0

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

GAINVAL6

GAINVAL7

GAINVAL8

__________

__________

__________

1.000

1.000

1.000

SP RAMP

SP RAMP

__________

TIME MIN

__________

FINAL SP

__________

PVHOTSTART

__________

SP RATE

__________

EU/HR UP

__________

EU/HR DN

__________

EU/HRUP2

__________

EU/HRDN2

__________

SP PROG

__________

 

 

DISABL

3

1000

DISABL DISABL 0

0

0

0

DISABL

4/00

UDC 3300 Process Controller Product Manual

75

Page 87
Image 87
Honeywell UDC 3300 manual Expanded Model DC330E-XX-XXX