Chapter 4 Retrofitting Options

To Retrofit A5 DC Power Input Assembly (Option 002)

4Insert and tighten the two hex screws (H4) and the lock washers (H5) onto the HP-IB connector that protrudes from the rear of the chassis using the 7-mm spin tight.

5Now, re-install the front bezel by performing the front bezel removal procedure, in Chapter 3 of this guide, in reverse. Be sure to insert A2 Display Board’s cable into connector J6 on

A1 Motherboard Assembly.

6Tighten the three H1 screws, shown in Figure 4-1A, to secure the motherboard to the chassis.

A4 AC Power Supply

Assembly

H1

H2

H2

J18

Figure 4-1B. DC Power Input Assembly Retrofitting

4-6

Assembly-Level Service Guide