Chapter 4 Retrofitting Options

To Retrofit A5 DC Power Input Assembly (Option 002)

7To install the new A4 AC Power Supply Assembly (53132-60207), connect the ac power supply’s shorter cable to connector J18 on A1 Motherboard Assembly as shown in Figure 4-1B.

8Insert and tighten the two TORX 10 screws (H2) to attach

A4 Power Supply Assembly to the rear of the chassis as shown in Figure 4-1B.

9Insert and tighten the TORX 15 screw (H1) into the upper-middle of the chassis as shown in Figure 4-1B.