Chapter 7 HP 53131A/132A Specifications
Measurement Specifications
Measurement Specifications
Frequency, Period
Channel 1 and 2 Range: | 0.1 Hz to 225 | MHz | 4.44 ns to 10 s | |
Channel 3 Range: |
|
|
|
|
Option 030 | 100 | MHz to 3 | GHz | 0.33 ns to 10 ns |
Option 050 | 200 | MHz to 5 | GHz | 0.2 ns to 5 ns |
Option 124 | 200 | MHz to 12.4 GHz | 80 ps to 5 ns | |
(Period 2 or 3 selectable only via the
For Automatic or External Arming:
(and signals < 100 Hz using Timed Arming)
LSD Displayed:
⎛ | tres ⎞ | × | Frequency | |
or | ||||
⎝ | ||||
|
|
| Period | |
RMS Resolution:
⎛ | tres2 + (2 × Trigger Error2 )⎞ | × | Frequency | |
⎜ | ⎟ | or | ||
⎝ | ⎠ |
| Period | |
|
|
|
| |
| HP 53131A | HP 53132A |
|
| |||
|
| tres |
| tres |
|
|
|
| typical | 650 ps |
| 200 ps |
|
|
|
| see graphs for worst case resolution performance |
| |||||
| For Automatic Arming: | Gate Time | N |
|
|
| |
| = |
| |||||
|
|
|
| Frequency |
| ||
| where N = 1 for Ch1 or Ch2 Frequency < 1 MHz | ||||||
|
| 4 for Ch1 or Ch2 Frequency > 1 MHz | |||||
|
| 128 for Ch3 |
|
|
|
| |
|
| ⎛ |
| ta cc | ⎞ | Frequency | |
|
|
| × | or | |||
Systematic Uncertainty: ⎝± Time Base Error | ± | ||||||
|
|
|
| Gate Time |
|
| Period |
|
|
|
|
|
|
| |
| HP 53131A | HP 53132A |
|
| |||
|
| tacc |
| tacc |
|
|
|
| typical | 350 ps |
| 100 ps |
|
|
|
| worst case | 1.25 ns |
| 500 ps |
|
|
|
Trigger: Default setting is Auto Trigger at 50%
For Time or Digits Arming:
LSD Displayed:
⎛ | 2 2 × tre s | tjitter | ⎞ | × | Frequency |
⎜ | + | ⎟ | or | ||
⎝ Gate Time × Number or Samples | Gate Time⎠ |
| Period | ||
RMS Resolution:
⎛ | 4 × tres2 + 2 × Trigger Error2 | tjitte r | ⎞ | Frequency |
⎜ | + | ⎟ x | or | |
⎝ Gate Time × Number or Samples | Gate Time⎠ | Period | ||
| HP 53131A | HP 53132A |
|
| ||
| tres | tjitter | tres | tjitter |
| |
| typical 500 ps | 50 ps | 225 ps | 3 ps |
| |
| see graphs for worst case resolution performance |
| ||||
| Number of Samples = |
|
|
|
| |
| Gate Time x Frequency | (Frequency < 200 kHz) | ||||
| Gate Time x 200,000 | (Frequency > 200 kHz) | ||||
|
| ⎛ | ta cc | ⎞ | Frequency | |
|
| × | or | |||
Systematic Uncertainty: ⎝± Time Base Error ± | ||||||
|
|
| Gate Time |
| Period | |
|
|
|
|
|
| |
| HP 53131A | HP 53132A |
|
| ||
|
| tacc | tacc |
|
|
|
| typical | 100 ps | 10 ps |
|
|
|
| worst case | 300 ps | 100 ps |
|
| |
Trigger: Default setting is Auto Trigger at 50%
7
The following graphs may also be used to compute errors for Period Measurements. To find the Period error (ΔP), calculate the frequency of the
input signal ( F = | 1 | ) and find the frequency error (ΔF) from the chart. Then, calculate the period error as: | ΔP = | ⎛ΔF⎞ | × P | |
⎠ | ||||||
| P |
|
| ⎝ F |
| |