11
Using PageScope Web Connection
Item | Description |
Sender name | Specify the sender name used when sending scan data attached to an e- |
| mail message. (maximum 20 characters) |
|
|
Specify the | |
|
|
Port Number | Specify the port number (between 1 and 65535) of the SMTP server. Nor- |
| mally, port number 25 is used. |
|
|
SMTP Server | Specify the amount of time until communication with the SMTP server |
Timeout | times out (between 30 and 300 seconds). |
|
|
Text Insert | Select to insert the body text of the |
|
|
Basic Mode/Ad- | Select the |
vanced Mode | sending documents as Internet faxes. |
|
|
Max. TX Size | Specify the maximum size for transmissions with advanced mode. |
|
|
Max. Resolution | Specify the maximum resolution for transmissions with advanced mode. |
|
|
Coding Mode | Specify the maximum compression encoding method for scan data to be |
| sent with advanced mode. |
|
|
POP3 Server Ad- | Specify the IP address or host name for the POP3 server. (maximum 64 |
dress | characters) |
|
|
Account Name | Specify the account name used to log on to the POP3 server. (maximum |
| 64 characters) |
|
|
Password | Specify the password used to log on to the POP3 server. (maximum 32 |
| characters) |
|
|
Auto Reception | Select whether or not the Auto Reception function is used. |
|
|
INTERVAL | Specify the time interval (between 1 and 60 minutes) for checking for new |
| |
|
|
Reply Address | Specify the |
| error occurs, a reply to the error message is sent to the |
| specified here. Normally, the |
| fied. (maximum 64 characters) |
|
|
Port Number | Specify the port number (between 1 and 65535) of the POP3 server. Nor- |
| mally, port number 110 is used. |
|
|
POP3 Server | Specify the amount of time (between 30 and 300 seconds) until the con- |
Timeout | nection with the POP3 server times out. |
|
|
Header Print | Select whether or not the header (title or sender) is printed. |
|
|
|
|