Reference

Window Process Set Up

The Window measurement process may be configured using the four parameters in the WINDOW Menu:

MODE: Defines window length in terms of "bits" or "seconds".

BITS: Window length in bits.

SECOND: Window length in terms of hours, minutes, and seconds.

REPORT: Turns end-of-window reports on or off.

If you want to measure Window results, you must set the MODE parameter, and depending on your MODE selection, either the BITS or SECOND parameter. In addition, if you want to generate end-of-window reports you must also set the REPORT parameter to on.

Procedure

1.Press F1 to enter the Menu system.

2.Select the WINDOW Menu (F3).

3.Within the WINDOW Menu, set up:

a.MODE (F2) and

b.either BITS (F3) or SECOND (F4).

4.Press MORE (F1) to see the next page of the WINDOW Menu.

5.If you are using a printer, set the REPORT parameter (F2) to on or off as required.

6.When WINDOW Menu setup is complete, press F1 multiple times to exit the Menu system.

See later in the this chapter for more information on setting up the WINDOW Menu.

3-34

GB1400 User Manual

Page 111
Image 111
Tektronix 071-0590-00 user manual Window Process Set Up, Procedure