Tektronix 071-0590-00 user manual Resus?, Resusper?, Totalbits?

Models: 071-0590-00

1 376
Download 376 pages 61.76 Kb
Page 273
Image 273

Remote Commands

res_us?

Results Unavailable Seconds. This command returns the total number of unavailable seconds counted, either in the current test interval so far or in the previous test interval, depending on the setup of TEST PREV and the current test state.

Min. Abbr.

res_us?

 

Returns

<NR1>

 

Example

res_us?

(command)

 

RES_US 120

(response)

res_us_per?

Results Unavailable Seconds Percentage. This command returns the percentage of unavailable seconds, either in the current test interval so far or in the previous test interval, depending on the setup of TEST PREV and the current test state.

Min. Abbr.

res_us_?

 

Returns

<NR2>

 

Example

res_us_per?

(command)

 

RES_US_PER 29.01

(response)

total_bits?

Totalize Bits Query. Returns the total number of bits accumulated in the current Totalize measurement interval. The Totalize bit count is zeroed at the start of each new Totalize measurement interval, that is at power-up and after each error reset.

Min. Abbr.

total_b?

 

Returns

<NR1>

 

Example

total_bits?

(command)

 

TOTAL_BITS 32365018072

(response)

GB1400 User Manual