Remote Commands

clock_step [v]

Clock Step. Sets the clock frequency increment/decrement default step size 10 kHz, 100 kHz, 1 MHz, 10 MHz, 100 MHz, or 1000 MHz.

Min. Abbr.

clock_ste

Arguments

v:

<NR3>, in the range: 0.010E+6, 0.100E+6,

 

 

1.000E+6, 10.000E+6, 100.000E+6 or 1000.000E+6

Example

clock_step 1.000E+6

clock_step?

Clock Step Query. Returns the current clock frequency step size.

Min. Abbr.

clock_ste?

 

Returns

<NR3>

 

Example

clock_step?

(command)

 

CLOCK_STEP 1.000E+6

(response)

clock_stp_up and clock_stp_dn

Clock Step Up, Clock Step Down. This command pair is used to increment or decrement the current Generator frequency using the step size previously defined with the clock_step command.

Min. Abbr.

clock_stp_u

 

clock_stp_d

Arguments

none

Example

clock_step_up

 

clock_step_dn

clock_stp_up [v] and clock_stp_dn [v]

Clock Step Up, Clock Step Down. This command pair is used to increment or decrement the current clock frequency by v, which can range from: 0.1 MHz to 1405 MHz, in 0.01 MHz steps.

Min. Abbr.

clock_stp_u

 

clock_stp_d

Arguments

v:

<NR3>, in the range 0.100E+6 to 1405.000E+6.

Example

clock_step_up 0.100E+6

 

clock_step_dn 0.100E+6

C-38

GB1400 User Manual

Page 256
Image 256
Tektronix 071-0590-00 user manual Clockstep?, Clockstpup and clockstpdn, Clockstpup v and clockstpdn