Tektronix 071-0590-00 user manual Dataoffup v and dataoffdn, Dataoffset?

Models: 071-0590-00

1 376
Download 376 pages 61.76 Kb
Page 262
Image 262

Remote Commands

Min. Abbr.

data_off_u

 

data_off_d

Arguments

none

Example

data_off_up

data_off_up [v] and data_off_dn [v]

Data Offset Up, Data Offset Down. This command pair is used to increment or decrement the current baseline offset of the Generator data output by a specified step size of [v] volts.

Min. Abbr.

data_off_u

 

data_off_d

Arguments

v: <NR2>, in the range 0.05 to 3.00, in steps of 0.05.

 

in the range 0.05 to 3.80 in 0.05 v steps (PECL option)

Example

data_off_up 0.20

data_offset [v]

Data Offset. Sets the baseline offset of the Generator data output to a specified value of [v] volts.

Min. Abbr.

data_offs

Arguments

v: <NR2>, in the range -2.00 to 1.00 in steps of 0.05.

 

in the range -2.00 to 1.80 in 0.05 v steps (PECL option)

Example

data_offset -0.50

data_offset?

Data Offset Query. Returns the current baseline offset of the Generator data output in terms of volts.

Min. Abbr.

data_offs?

 

Returns

<NR2>

 

Example

data_offset?

(command)

 

DATA_OFFSET -0.50

(response)

C-44