Tektronix 071-0590-00 user manual Measurements, Ber

Models: 071-0590-00

1 376
Download 376 pages 61.76 Kb
Page 172
Image 172

Specifications

SYNC thresholds

PRBS mode 25% (1024 erros/4096 bits)

 

WORD mode 3.1% (128 errors/ 4096 bits)

 

Optional 1 Mbit WORD thresholds, programmable

 

 

 

 

 

 

Level

BER

Ratio (Errors/bits)

 

 

1

3.1E-2

256/8192

 

 

2

7.8E-3

256/32768

 

 

3

1.9E-3

256/131072

 

 

4

9.7E-4

256/262144

 

 

5

4.8E-4

256/524288

 

 

6

2.4E-4

256/1048576

 

 

7

1.2E-4

256/2097152

 

 

8

6.1E-5

256/4194304

 

 

9

3.0E-5

256/8388608

 

Measurements

BER Measurements

Three simultaneous BER measurements (Totalize, Window and Test) displayed as:

BER

9.9E-01 to <1.0E-16

Totalize

0 to 99999999, then 1.0E8 to 9.9E36

Totalize Mode

BER since power on or reset

Window Mode

BER over sliding window,

 

programmable in time (1-sec to 24 24-hrs) or bits (1E-8-1E-16)

Test Mode

BER over time of test, programmable in time (1-sec to 24-hrs). Additional

 

calculations include ES, EFS, TES, SES, DM, US, and LOS.

Frequency

System Clock Frequency, 10 KHz resolution

History Indicators

SYNC loss, Bit Error, Phase Error, Power

A-8

GB1400 User Manual

Page 172