Tektronix 071-0590-00 user manual Testthres?

Models: 071-0590-00

1 376
Download 376 pages 61.76 Kb
Page 297
Image 297

Remote Commands

test_thres [v]

Test Threshold. Used to set the test error rate threshold to the value: 1 x 10-v. This threshold determines which seconds are counted as Threshold Errored Seconds (TES). It also determines when On-Error reports are generated.

Min. Abbr.

test_t

 

Arguments

v

<NR1>, in the range 2, 3, ..., 16. That is the test

 

 

error

 

 

rate threshold may be set in the range 10-2to 10-16.

Example

test_thres 12

test_thres?

Test Threshold Query. Returns the value v, indicating that the current test error rate threshold is set to 1 x 10-v.

Min. Abbr.

test_t?

 

Returns

<NR1>

 

Example

test_thres?

(command)

 

TEST_THRES 12

(response)

 

indicating that the test error rate threshold

 

is set to 1 x 10-12.

 

GB1400 User Manual

C-79

Page 297
Image 297
Tektronix 071-0590-00 user manual Testthres?