Tektronix 071-0590-00 user manual Reses?, Resesper?, Reslos?

Models: 071-0590-00

1 376
Download 376 pages 61.76 Kb
Page 269
Image 269

Remote Commands

res_es?

Results Errored Seconds. This command returns the total number of errored seconds counted, either in the current test interval so far or in the previous test interval, depending on the setup of TEST PREV and the current test state.

Min. Abbr.

res_es?

 

Returns

<NR1>

 

Example

res_es?

(command)

 

RES_ES 384

(response)

res_es_per?

Results Error-Free Seconds Percentage. This command returns the percentage of errored seconds calculated, either in the current test interval so far or in the previous test interval, depending on the setup of TEST PREV and the current test state.

Min. Abbr.

res_es_?

 

Returns

<NR2>

 

Example

res_es_per?

(command)

 

RES_ES_PER 89.35

(response)

res_los?

Results Loss of Signal Seconds. This command returns the total number of seconds counted, that contained a loss of signal event, either in the current test interval so far or in the previous test interval, depending on the setup of TEST PREV and the current test state.

Min. Abbr.

res_l?

 

Returns

<NR1>

 

Example

res_los?

(command)

 

RES_LOS 1

(response)

GB1400 User Manual