Standard Event Status Enable Register

Different conditions within the Standard Event Status Register can be individually enabled or disabled. The Standard Event Status Enable Register contains enabling bits. Each time one of the event conditions or one of the enabling bits change, the status of the ESB bit is re-evaluated. If any status bit is set and its corresponding enable bit is set, the ESB bit is set also.

Each time the GB1400 is powered on, this byte is reset so that no bits are enabled. The bit definition for the Standard Event Status Enable Register is the same as it is for the Standard Event Status Register.

Test Status Event Register (Analyzer only)

The TSB bit is the summary of the Test Status Event Register. This byte has an enabling byte which works in a similar manner to the above Status Byte. The individual bits within the Test Status Event Register represent the different conditions which might cause a Test Event. The bit definitions for the Test Status Event Register are as follows.

Bit 1

End-of Window

Set at the end of each window period

 

condition

 

Bit 2

End-of-Test condition

Set at the end of each Test

Bit 3

Threshold Error

Set whenever Test is running and Errored

 

condition

Second occurs, where error rate is above Test

 

 

Error Rate Threshold

Bit 4

Synchronization Loss

Set whenever SYNC LOSS occurs

 

condition

 

Bit 5

Phase Error condition

Set whenever a Phase Error occurs

Bit 6

Auto Synchronization

Set whenever AUTO SEARCH locks on a Data

 

complete

Pattern

Bit 7

 

Not Used

Bit 8

 

Not Used

Test Status Event Enable Register (Analyzer only)

The different conditions within the Test Status Event Register can be individually enabled and disabled. The Test Status Event Enable Register contains enabling bits. Each time one of the event conditions or one of the enabling bits change, the status of the TSB bit is re-evaluated. If any status bit is set and its corresponding enable bit is set, the TSB bit will set. Each time the GB1400 is powered on, this byte is reset so that no bits are enabled. The bit definition for the Test Status Event Enable Register is the same as for the Test Status Event Register.