Reference

End-of-Window Reports

When enabled, an End-of-Window report will occur once every second. The results of an End-of-Window report are based on a sliding interval T, where T is set in terms of bits or time (hours:minutes:seconds). Use the REPORT parameter in the WINDOW Menu to enable or disable End-of-Window reports. Use the MODE, BITS, and SECOND parameters in the WINDOW Menu to set window length T. An example End-of-Window report is shown below.

Example End-of-Window Report

Date:

Jun/14/99

Time:

02:42:34.46

 

Bits= 5.00E+08

Errs= 5000

Err rate= 1.0E-04

Freq= 100.00 MHz

Pattern= AA55

Data los= 0

Sync Los= 0

Phase Err= 0

Procedure to Enable or Disable End-of-Window Reports

1.Complete the Basic Report Setup Procedure.

2.Press F1 to enter the Menu system.

3.Select the WINDOW Menu (F3).

4.Press F1 to see the second page of the WINDOW Menu.

5.Select the REPORT parameter (F2).

6.Set the REPORT parameter to ON. Press F4 to lock in this choice.

7.Exit the Menu system by pressing F1 multiple times until the normal display format appears.

3-40

GB1400 User Manual

Page 117
Image 117
Tektronix 071-0590-00 user manual End-of-Window Reports, Example End-of-Window Report