Remote Commands

Error Injection Commands

error_rate [offextrate_3rate_4rate_5rate_6rate_7]

Error Rate. Sets the Generator output bit error injection rate to "off", "external", or one of the following specified values: 10-3, 10-4, 10-5, 10-6, or 10-7.

Min. Abbr.

error_r

 

Arguments

off:

turns error injection off.

 

ext:

selects the external error injection mode.

 

rate_3

sets bit error injection rate to 10-3.

 

rate_4

sets bit error injection rate to 10-4.

 

rate_5

sets bit error injection rate to 10-5.

 

rate_6

sets bit error injection rate to 10-6.

 

rate_7

sets bit error injection rate to 10-7.

Example

error_rate rate_6

error_rate?

Error Rate Query. Returns a character string indicating the current Generator output error injection mode and rate.

Min. Abbr.

error_r?

 

Returns

[offextrate_3rate_4rate_5rate_6rate_7]

 

Example

error_rate?

(command)

 

ERROR_RATE RATE_6

(response)

error_single

Error Single. This command injects a single bit error into the Generator output signal.

Min. Abbr.

error_s

Arguments none

Exampleerror_single

C-46

GB1400 User Manual

Page 264
Image 264
Tektronix 071-0590-00 user manual Errorrate offextrate3rate4rate5rate6rate7, Errorrate?, Errorsingle