Remote Commands

total_error?

Totalize Error Query. Returns the number of bit errors counted so far in the current Totalize measurement interval. The Totalize error count is zeroed at the start of each new Totalize measurement interval, that is at power-up and after a error reset.

Min. Abbr.

total_e?

 

Returns

<NR1>

 

Example

total_error?

(command)

 

TOTAL_ERROR 20984

(response)

total_rate?

Totalize (Bit Error) Rate Query. Returns the bit error rate (BER) calculated so far in the current Totalize measurement interval. Totalize BER equals the Totalize bit error count divided by the Totalize bit count. The number will reset at power-up and on error reset.

Min. Abbr.

total_r?

 

Returns

<NR3>

 

Example

total_rate?

(command)

 

TOTAL_RATE 8.62E-6

(response)

total_time?

Totalize Time Query. Returns a quoted string indicating the amount of time accumulated in the current Totalize measurement interval. Totalize time is zeroed at the start of each new Totalize measurement interval, that is at power-up and after each error reset.

Min. Abbr.

total_t?

 

Returns

<qstring>, in the format "ddd-hh:mm:ss" where ddd = days,

 

hh = hours (00 ...

23), mm = minutes (00 ... 59), ss = seconds (00

 

... 59)

 

Example

total_time?

(command)

 

"000-12:34:56"

(response)

C-56

GB1400 User Manual

Page 274
Image 274