Remote Commands

Generator Commands

The following commands are found only in the Generator command set.

Clock Source and Frequency Setup Commands

clock_freq [v]

Clock Frequency. Sets the clock frequency to a value [v], specified in Hz, over the range of 1 MHz to 1405 MHz in steps of 1kHz.

Min. Abbr.

clock_f

 

Arguments

v

<NR3>, in the range 1.000E+6 to 1405.000E+6 in steps

 

of 0.001E+6.

Example

clock_freq 622.000E+6.

clock_freq?

Clock Frequency Query. Returns the current Generator clock frequency setting.

Min. Abbr.

clock_f

 

Returns

<NR3>

 

Example

clock_freq?

(command)

 

CLOCK_FREQ 0.150E+6

(response)

clock_memory?

Clock Memory Query. Returns the contents of all ten frequency memory locations. The response will be 10 message units separated by semi-colons ";", and will contain the memory location and frequency.

Returns

<NR1 Numeric>

 

<NR3 Numeric>