Tektronix 071-0590-00 user manual Data Patterns, Data Output True and Complement

Models: 071-0590-00

1 376
Download 376 pages 61.76 Kb
Page 166
Image 166

Specifications

Data Patterns

 

Format

NRZ-L, Normal and Complement

Type

PRBS or WORD (User-programmable)

PRBS Patterns

2n-1; n=7,15,17,20,23

WORD Lengths

8 and 16-bit only,

 

1 Mbit memory (with optional memory)

PRBS Phase Tap Information

The Pseudo-Random data patterns used in the GB1400 TX are generated by shift-register and exclusive-OR feedback technique. The pattern is dependent on which feedback taps (shift register outputs) are selected.

For example, PN7 is defined as a seven-stage shift register, which the output of stages 6 and 7 fed back (through an exclusive-OR gate) to the beginning of the shift register. The feedback taps used in the GB1400 are tabulated here.

Pattern

Feedback

Taps

PN7

6

7

PN15

14

15

PN17

14

17

PN20

17

20

PN23

18

23

Data Output (True and Complement)

Amplitude

Variable 0.5V to 2.0V, 50 mV steps

Baseline Offset

Variable -2.0V to +1.0V, 50 mV steps

 

-2.0V to +1.8V, 50 mV steps, with PECL option

Pulse Top Limit

+2.0V into 50 Ohms, +4.0V open load

 

+2.8V into 50 Ohms (with PECL option)

Rise/Fall Time

150 pS, typical (20-80%) at 1V amplitude

Source Impedance

50 Ohms

Output Timing

CLOCK/DATA edge-aligned (+/- 100 pS)

Jitter:

100 pS, peak-to-peak Max. referenced to EXT clock

Connectors

SMA

Data Inhibit

Rear panel SMA, ECL (50 Ohms to -2V term)

Data Inhibit Rate

Asynchronous, 1 bit and 500 pS minimum width

Data Invert

Front Panel Selectable

A-2

GB1400 User Manual

Page 166
Image 166
Tektronix 071-0590-00 user manual Data Patterns, Data Output True and Complement