Tektronix 071-0590-00 user manual Dispselect total window test, Dispselect?, Errorreset

Models: 071-0590-00

1 376
Download 376 pages 61.76 Kb
Page 288
Image 288

Remote Commands

disp_select [total window test]

Display Select. Selects the total, window, or test display mode. The display mode determines which BER and bit error results are shown in the top-middle, and top-right fields respectively of the display.

Min. Abbr.

dis

Arguments

total: selects the Totalize display mode, Totalize Error

 

Rate/Total

 

window: selects the Window display mode, Window Error Rate/

 

Total

 

test: selects the Test display mode, Test Error Rate/Total

Example

disp_select test

disp_select?

Display Select Query. Returns a character string that indicates the current display mode of the Analyzer.

Min. Abbr.

dis?

 

Returns

[total window test]

 

Example

disp_select?

(command)

 

DISP_SELECT TEST

(response)

error_reset

Error Reset. This command resets the Totalize and Window measurement processes. This does not affect Test results.

Min. Abbr.

er

Arguments none

Exampleerror_reset

C-70

GB1400 User Manual

Page 288
Image 288
Tektronix 071-0590-00 user manual Dispselect total window test, Dispselect?, Errorreset