Remote Commands

auto_thresh [n]

Auto_Thresh. Sets the Error Rate Threshold used when Auto Search is in BER mode. This the exponent for the error rate used for the Delay settings, in terms of 10E-n

Arguments

n:

3 to 10

Example

auto_thresh 3

auto_thresh?

Returns the exponent of the number used as the Data Delay Error Rate Threshold.

Response

<NR1 Numeric>

auto_width?

Returns the Width of the Data Eye as determined by Auto Search, in either mode. These values are in terms of seconds. (Example, 100E-12 is 100 pS.) The following delay error codes are returned if appropriate:

1Only 1 Data Eye Crossing found

2No Data Eye Crossing found

3Auto Search not run

Response

<NR1 Numeric>

GB1400 User Manual

C-69

Page 287
Image 287
Tektronix 071-0590-00 user manual Autothresh n, Autothresh?, Autowidth?