Tutorial

B.Locate the controls in the PATTERN box of the Generator. Make sure the PRBS button is enabled (the LED inside this switch should be ON). Set the Generator pattern to a 223-1 bit PRBS as follows:

Set this parameter

…to this value

…using this procedure.

 

 

 

PRBS type

PN 23

Press pattern up/down arrow keys until

 

 

PATTERN is set to PN 23

 

 

 

C.Locate the controls in the ERROR INJECT box of the Generator. Verify

that the Generator ERROR RATE GENERATOR is OFF (the LED within the switch should

be OFF). If the LED in the error inject RATE key is ON, then press RATE one or more times until it turns off.

4.Setup Analyzer for “AUTO-SEARCH” Operation.

A.Locate the controls in the SYNC box of the Analyzer. Verify that the Analyzer AUTO SEARCH function is ENABLED. The LED in the AUTO SEARCH key should be ON. If the LED is OFF, press the AUTO SEARCH function one time until the LED is O N. At this point, verify that the green LOCK LED is ON.

B.Locate the controls in the ERROR DETECTION box of the Analyzer. Zero all Analyzer error counts by pressing the CLEAR key. Confirm that the number of errors and the error rate were reset to 0 (note: error rate will start changing as more and more bits are received. After several minutes of operation, the error rate should reach 0.0E-90.0E-100.0E-11 and on).

C.Locate the controls in the ERROR HISTORY box of the Analyzer. Reset all Analyzer history LEDs by pressing this CLEAR key. Confirm that all ERROR HISTORY LED’s are turned OFF.

D.Locate the controls in the ERROR INJECT box of the Generator. Verify the GB1400 Analyzer can detect errors by pressing the Generator ERROR INJECT SINGLE key several times. Verify that the number of errors count displayed by the Analyzer increments each time the Generator SINGLE key is pressed.

In effect you are now performing a bit error rate test on the test cables connecting the gigaBERT1400 Generator and Analyzer. In an actual BER test, gigaBERT1400 Generator clock and data outputs would be connected to inputs on a "device under test" (DUT) while gigaBERT1400 Analyzer inputs would be connected to outputs on the DUT.