4.83 Transmit Function Address (TXFUNCADDR)

The Transmit Function Address (TXFUNCADDR) is shown in Figure 98 and described in Table 99.

 

 

Figure 98. Transmit Function Address (TXFUNCADDR)

7

6

0

Reserved

 

FUNCADDR

R-0

 

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Table 99. Transmit Function Address (TXFUNCADDR) Field Descriptions

Bit

Field

Value

Description

7

Reserved

0

Reserved

6-0

FUNCADDR

0-7Fh

Address of target function

4.84 Transmit Hub Address (TXHUBADDR)

The Transmit Hub Address (TXHUBADDR) is shown in Figure 99 and described in Table 100.

 

 

Figure 99. Transmit Hub Address (TXHUBADDR)

7

6

0

MULT_TRANS

 

HUBADDR

R/W-0

 

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Table 100. Transmit Hub Address (TXHUBADDR) Field Descriptions

Bit

Field

Value

Description

7

MULT_TRANS

0-1

Set to 1 if hub has multiple transaction translators. Cleared to 0 if only single transaction translator

 

 

 

is available.

6-0

HUBADDR

0-7Fh

Address of hub

4.85 Transmit Hub Port (TXHUBPORT)

The Transmit Hub Port (TXHUBPORT) is shown in Figure 100 and described in Table 101.

 

 

Figure 100. Transmit Hub Port (TXHUBPORT)

7

6

0

Reserved

 

HUBPORT

R-0

 

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Table 101. Transmit Hub Port (TXHUBPORT) Field Descriptions

Bit

Field

Value

Description

7

Reserved

0

Reserved

6-0

HUBPORT

0-7Fh

Port number of the hub