Total Access 600 Series System Manual

Section 4 User Interface Guide

 

 

Ethernet Interface Setup Instructions

Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface.

Step

Action

1From the main menu, select INTERFACES.

2Highlight the CONFIG menu for the ETH interface and press <ENTER>.

3Use the right arrow to select AUTONEGOTIATION and press <ENTER>. Use the down arrow to choose OFF.

4Select the DATA RATE field and specify either 10BASET or 100BASET.

5Select the DUPLEX TYPE field and specify either HALF DUPLEX or FULL DUPLEX.

.2. Configuring the Layer 2 Protocol

For more details on the configuration parameters discussed in this section, refer to the following pages: Layer 2 ATM Network Interface Protocol menus beginning on page 101

 

Layer 2 Protocol (ATM) Configuration – T1 Interface

 

 

 

 

Step

Action

 

 

1

From the main menu, select L2 PROTOCOL and press <ENTER>.

 

 

2

Use the arrow keys to select the PROTOCOL field for the T1 interface. Press

<ENTER>. Select ATM from the list of available protocols.

 

 

 

3

Use the arrow keys to select the CONFIG menu for the T1 interface and press

<ENTER>.

 

 

 

4

Highlight the ATM CONFIG menu for the T1 interface and press <ENTER>.

 

 

5

Enter the IDLE CELLS format for your network.

 

 

6

Set DATA SCRAMBLING appropriately for your network.

 

 

7

Back all the way out to one level to the PVC CONFIG menu, and press <ENTER>.

Enter the VPI and VCI values for communicating with that Gateway. Select

 

ROUTER under the CONNECTION field.

 

 

 

Select the SETUP menu and configure the virtual circuit for IP or PPP operation.

8

(Our example selects IP.) Refer to L2 Protocol (ATM–NET–ATM) > Config >

 

PVC Config > Setup (Router) on page 103 for more details.

 

 

61200624L1-1B

© 2004 ADTRAN, Inc.

181

Page 183
Image 183
ADTRAN 624, 612, 616, 606, 604 Ethernet Interface Setup Instructions, PVC Config Setup Router on page 103 for more details