Total Access 600 Series System Manual

Section 4 User Interface Guide

 

 

 

 

 

 

 

T1 Interface Setup Instructions

 

 

 

 

 

 

 

 

 

Step

Action

1From the main menu, select INTERFACES.

2Highlight the CONFIG menu for the T1 interface and press <ENTER>.

3Right arrow to select FORMAT and choose ESF or SF.

This format must match the format used by the other units in the network.

4

Set the LINE CODE to B8ZS or AMI.

This line code must match the line code used by the other units in the network.

5Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.

6Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.

Ethernet Interface Setup Instructions

Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface.

Step

Action

1From the main menu, select INTERFACES.

2Highlight the CONFIG menu for the ETH interface and press <ENTER>.

3Use the right arrow to select AUTONEGOTIATION and press <ENTER>. Use the down arrow to choose OFF.

4Select the DATA RATE field and specify either 10BASET or 100BASET.

5Select the DUPLEX TYPE field and specify either HALF DUPLEX or FULL DUPLEX.

61200624L1-1B

© 2004 ADTRAN, Inc.

175