ADTRAN 604, 612 Indicates the port of the FXO module, Displays the status of the FXO signal bits

Models: 606 624 612 616 604

1 264
Download 264 pages 28.45 Kb
Page 89
Image 89

Total Access 600 Series System Manual

Section 4 User Interface Guide

 

 

INTERFACES (FXO) > CONFIG

Configure the FXO mode, line impedance, and Tandem parameters from this menu.

INTERFACES (FXO) > CONFIG > PORT

Indicates the port of the FXO module.

INTERFACES (FXO) > CONFIG > MODE

Choices are given below. Default is LOOP START.

This mode must match the network configuration and/or how each port is being used. Each port on the FXO Module is independent and should be set accordingly.

LOOP START

GROUND START

DPT

MODIFIED DPT

Sets the port to use FXO loop start signaling on the T-span and loop start supervision on the analog 2-wire interface.

Sets the port to use FXO ground start signaling on the T-span and ground start supervision on the analog 2-wire interface.

Sets the port to use Dial Pulse signaling to terminate dialed numbers.

Sets the port to use DPT signaling on the interface. In DPT mode, digits are transmitted out the FXO interface to the user equipment. DPT mode is one-way operation for outbound calls towards user equipment on the 2-wire side.

INTERFACES (FXO) > CONFIG > TX (dB)

Sets the TX direction level points. This signal will change the volume of the voice. TX (dB) is the signal that is transmitted out the T1, with 0 dB being the strongest. If the volume is too loud across the T1, this number should be increased. A higher number indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default is 0.0 dB.

INTERFACES (FXO) > CONFIG > RX (dB)

Sets the RX direction level points. This signal will change the volume of the voice for the signal being transmitted by the Total Access 6XX out the interface. A higher number indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default is 0.0 dB.

INTERFACES (FXO) > CONFIG > SVC MODE

Indicates whether the module is IN SERVICE or OUT OF SVC. This does not indicate whether the port has been mapped.

INTERFACES (FXO) > STATUS

Displays the status of the FXO signal bits.

61200624L1-1B

© 2004 ADTRAN, Inc.

87

Page 89
Image 89