Section 5 DLP-1

Total Access 600 Series System Manual

 

 

Perform the steps below in the order listed.

1.Connecting a VT100 terminal to Total Access 6XX:

Set the parameters of the VT100 terminal or PC to:

9600 baud rate

8 data bits

No parity

1 stop bit

No flow control

If the terminal has a parallel setting, disable it and use the serial port.

Using the CRAFT Port

Plug the RJ-48 end of the data cable into the Total Access 6XX CRAFT port on the back of the unit. Make the connection to the VT100 terminal as appropriate for your equipment.

2.Connect a PC emulating a VT-100 terminal to Total Access 6XX.

Most personal computers (PCs) or laptops can run communications software that emulates a VT100 terminal. Examples include Windows programs such as Terminalor Hyperterminal. However, there are many other adequate, commercially available software packages which will allow your PC or laptop to emulate a VT100 terminal.

Set the parameters of the communications software to:

9600 baud rate

8 data bits

No parity

1 stop bit

No flow control

Set the PC for direct connect on the appropriate com port (instead of dial up connection).

Using the CRAFT Port

Plug the RJ-48 end of the data cable into the Total Access 6XX CRAFT port on the back of the unit. Make the connection to the VT100 terminal as appropriate for your equipment.

You are now ready to log in to the Total Access 6XX, as described in DLP-2, Logging in to the System.