Section 5 DLP-14

Total Access 600 Series System Manual

 

 

Tools and Materials Required

VT100 compatible terminal or computer with terminal emulation software

Appropriate cable to connect terminal to the unit (customer-provided)

DB-9 female to RJ-48 female adapter (ADTRAN proprietary) for connecting to the CRAFT port on the rear of the unit (see CRAFT Port on page 31).

Perform the steps below in the order listed.

Upgrade From A.03 to A.03.92 (Transition Build) to A.04

1.Upgrade the firmware from A.03 to A.03.92 (Transition Build) firmware. See DLP-7(TFTP) or DLP-8(XMODEM) for instructions on how to perform this upgrade.

2.Once the upgrade to A.03.92 is complete, immediately upgrade the unit to A.04. See DLP-7(TFTP) or DLP-8(XMODEM) for instructions on how to perform this upgrade.

Upgrading from A.03 to A.03.90 (Transition Build) to A.04 will save the unit's configuration.

Upgrade From A.03 to A.04 Directly

1.Upgrade the firmware from A.03 to A.04 firmware. See DLP-7(TFTP) or DLP-8(XMODEM) for instructions on how to perform this upgrade.

2.The unit must then be factory defaulted by one of the following methods:

Select SYSTEM UTILITY>TERMINAL MODE. At the > prompt, type fac. You will then see “Restore Factory Defaults and Reset Unit? (press 'y').” Press the y key to confirm default. The unit will then automatically reset.

3.Reconfigure the unit for the specific application.

Upgrading from A.03 to A.04 directly (or from A.04 to A.03 directly) will erase the unit's configuration.

222

© 2004 ADTRAN, Inc.

61200624L1-1B

Page 224
Image 224
ADTRAN 604, 612, 616, 606, 624 Upgrade From A.03 to A.03.92 Transition Build to A.04, Upgrade From A.03 to A.04 Directly