Total Access 600 Series System Manual

Section 4 User Interface Guide

 

 

T1 Interface Setup Instructions (Continued)

This line code must match the line code used by the other units in the network.

5Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.

6Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.

DSX-1 Interface Setup Instructions

Step

Action

1From the main menu, select INTERFACES.

2Highlight the CONFIG menu for the DSX interface and press <ENTER>.

3Right arrow to select FORMAT and choose ESF or SF.

This FORMAT must match the format used by the equipment connected to the DSX-1 interface. A FORMAT mismatch normally results in a Red Alarm condition.

4

Set the LINE CODE to B8ZS or AMI.

This line code must match the line code used by the equipment connected to the DSX-1 interface.

5Set the EQUALIZATION or line build out. The default setting of 0 DB is usually sufficient.

6Set the CSU LPBK option to ENABLE, DISABLE, or DISABLE ALL based on whether looping to this unit from another unit will be allowed.

2.Mapping the DS0s

For more details on the configuration parameters discussed in this section, refer to the following pages:

DS0 Map menus beginning on page 149