Network Turnup Procedure

Total Access 600 Series System Manual

 

 

5.MOUNTING OPTIONS

All units may be wallmounted or installed in a table-top application. In addition, the Total Access 612/616/624 units are available for 19- or 23-inch rackmount installations. Wallmount brackets are included with the unit and are already attached. For a rackmount installation, optional rackmount brackets must be purchased (19” – P/N 1200627L1, 23” – P/N 1200627L2).

Be careful not to upset the stability of the equipment mounting rack when installing this product.

Wallmounting the Unit

Tools Needed

The unit mounts and connects with standard fasteners and hand tools:

Four #8 x 3/4-inch pan-head wood screws

Drill and drill bit set

Flat head screwdriver (medium)

Two Phillips head screwdrivers (small/medium)

Wire-wrap gun (optional)

25-pair male amphenol cable (customer connection)

Selected punch-down block and tool

Follow these steps to wallmount the unit:

 

Wallmount Installation

 

 

Step

Action

 

 

1.

Decide on a location for the unit. Keep in mind that the unit needs to be mounted at or below

 

eye-level so that the LEDs are viewable.

 

IMPORTANT! Mount the chassis with LEDs facing to the side or down as shown in Figure 1 on

 

page 39 (not facing up).

 

Refer to Figure 2 on page 39 for a wallmount illustration.

 

 

2.

Prepare the mounting surface by attaching a board (typically plywood, 3/4” to 1” thick) to a wall

 

stud.

 

IMPORTANT! Mounting to a stud ensures stability. Using sheetrock anchors may not provide

 

sufficient long-term stability.

 

 

3.

Have someone else hold the unit in position as you install two #6 to #10 (1 1/2” or greater in

 

length) wood screws through the unit’s brackets and into the mounted board.

 

 

4.

Proceed to the steps given in Supplying Power to the Unit on page 40.

 

 