Section 5 DLP-3

Total Access 600 Series System Manual

 

 

Perform the steps below in the order listed.

1.Connect the Total Access 6XX unit to your VT100 system (details found in DLP-1,Connecting a VT100 Terminal or PC to the CRAFT Port).

2.Log in to the system.

3.From the ROUTER/CONFIG menu, select the INTERFACES option and press <Enter>.

4.Select SETUP for the ETH interface, then PRIMARY IP.

5.Highlight the IP ADDRESS field and press <Enter>. Enter the appropriate IP address (as given by your system administrator).

6.Highlight the SUBNET MASK field and press <Enter>. Enter the appropriate subnet mask (as given by your system administrator).

7.Use the left arrow key to back out to the ROUTER/CONFIG menu. Select ROUTES and press <Enter>. Use the arrow key to highlight the DEFAULT GATEWAY field and press <Enter>. Enter the appropriate default gateway (as given by your system administrator).

8.Press the left arrow key to back out to the main ROUTER menu. This action saves your changes and requires confirmation.

The presence of an asterisk in the lower right corner of the menu window indicates that changes have NOT been saved to flash memory. Changes are automatically saved to flash as the user backs out of the menu system or after a manual save (by pressing <CTRL+W>. Always ensure that the asterisk is not present before logging off the system. Failure to save changes could result in a configuration loss if a power failure occurs. (For more details on the asterisk indicator, refer to Config Status on page 45.

9. Log off the system by pressing <CTRL+L>.