Total Access 600 Series System Manual

Section 2 Engineering Guidelines

 

 

1.EQUIPMENT DIMENSIONS

Total Access 600R, Total Access 604/608

The Total Access 600R and Total Access 604/608systems measure 11.25” W, 7.5” D, and 2” H and come equipped for table top or wallmount use.

Total Access 612/616/624

The Total Access 612/616/624 systems measure 17” W, 8.5” D, and 1.75” H and come equipped for table top or wallmount use. These systems may be utilized in 19- or 23-inch racks with the purchase of mounting brackets (19”– P/N 1200627L1 and 23”– P/N 1200627L2).

2.POWER REQUIREMENTS

The following power requirements apply:

Table 1. AC Power Requirements

 

Maximum Power

Maximum Current

System

Consumption

Draw

 

 

 

 

 

 

Total Access 600R

14 W

300mA

 

 

 

Total Access 604

14 W

300 mA

 

 

 

Total Access 608

17 W

300 mA

 

 

 

Total Access 612

28 W

1.3 A

 

 

 

Total Access 616

32 W

1.3 A

 

 

 

Total Access 624

40 W

1.3 A

 

 

 

3.REVIEWING THE FRONT PANEL DESIGN

Total Access 600R

Figure 2 shows the Total Access 600R front panel.

LAN

WAN

Figure 1. Total Access 600R Front Panel Layout

61200624L1-1B

© 2004 ADTRAN, Inc.

23

Page 23
Image 23
ADTRAN 624, 612, 616, 606, 604 system manual Equipment Dimensions, Power Requirements, Reviewing the Front Panel Design