Section 5 DLP-5

Total Access 600 Series System Manual

 

 

Perform the steps below in the order listed.

1.Connect the computer to the Total Access 6XX CRAFT interface (details in DLP-1,Connecting a VT100 Terminal or PC to the CRAFT Port).

2.Log in to the unit.

3.Select the SYSTEM CONFIG/MANAGEMENT/TELNET ACCESS menu and set the TELNET ACCESS to ON.

4.Under the SYSTEM CONFIG/MANAGEMENT/TELNET ACCESS menu, select the TELNET USER LIST; press

<Enter>. The following screen appears.

5.Use the right arrow key to select the NAME field; press <Enter>. All new Telnet entries have a INACTIVE as the NAME. Enter a specific username to use for Telnet login. Each Telnet entry in the list must have a unique assigned name because duplicate names are not allowed.

6.Use the right arrow key to select PASSWORD; press <Enter>. Enter a password to use for Telnet logins.

7.Use the right arrow key to select IDLE TIME (MINS); press <Enter>. This field defines the amount of time in minutes the Telnet session may be idle before the user is logged off. The range is 1-255 and the default value is 10 minutes. Enter the appropriate IDLE TIME.

8.Use the right arrow key to select LEVEL; press <Enter>. Select the appropriate security level. (Reference DLP-6,Adding/Removing Users and Changing Password Security Levels, for security level definitions.)

9.This completes the addition of one Telnet user. Repeat steps 1-11 for each additional Telnet user access.

10.Press the left arrow key to escape out to the main menu. This saves your changes.

The presence of an asterisk in the lower right corner of the menu window indicates that changes have NOT been saved to flash memory. Changes are automatically saved to flash as the user backs out of the menu system or after a manual save (by pressing <CTRL+W>. Always ensure that the asterisk is not present before logging off the system. Failure to save changes could result in a configuration loss if a power failure occurs. (For more details on the asterisk indicator, refer to Config Status on page 45.

196

© 2004 ADTRAN, Inc.

61200624L1-1B

Page 198
Image 198
ADTRAN 624, 612, 616, 606, 604 system manual DLP-5 Total Access 600 Series System Manual