Section 2 Engineering Guidelines

 

Total Access 600 Series System Manual

 

 

 

 

Table 13. Specifications (Continued)

 

 

 

 

Application

Feature

 

Specification

 

 

 

 

Analog Ports

 

 

 

 

Number of FXS Ports

4 ports for Total Access 604

 

 

8 ports for Total Access 608

 

 

12 ports for Total Access 612

 

 

16 ports for Total Access 616

 

 

24 ports for Total Access 624

 

 

 

 

Modes

FXS Loop Start

 

 

FXS Ground Start

 

 

TR08 Single

 

 

TR08 UVG

 

 

DP0

 

 

Tandem (E&M)

 

 

 

 

Ringing

Balanced ringing, 5 REN per port not to exceed

 

 

35 REN

 

 

 

 

Ring Voltage

Fixed 70 VACrms with 20 VDC offset

 

 

 

 

Routing (Ethernet)

 

 

 

 

 

 

 

Specifications

IEEE 802.3

 

 

 

 

IP Support

TCP, RIP V1, RIP V2, UDP, ICMP, ARP, UDP

 

 

Relay, SYSLOG

 

 

 

 

PPP Support

LCP, IPCP, BCP

 

 

 

 

DHCP

DHCP Server to LAN

 

 

DHCP from network

 

 

 

 

Management

 

 

 

 

 

 

 

CRAFT Interface

EIA 232, Physical RJ-48C

 

 

 

 

Ethernet 10/100BaseT

SNMP V1 support

 

Interface

604/608 ATM units running D.01.36

 

 

 

firmware or previous

 

 

612/616/624 ATM units running D.01.30

 

 

 

firmware or previous

 

 

SNMP V2 support

 

 

TDM units running A.04 firmware or later

 

 

Full menu-driven Telnet access

 

 

Software download via TFTP

 

 

Support for VoDSL gateway management

 

 

systems and firmware download

 

 

 

 

36

© 2004 ADTRAN, Inc.

61200624L1-1B

Page 36
Image 36