Agilent Technologies 1680/90-Series Logic Analyzer
 Agilent 1680/90-Series Logic Analyzer-At a Glance
Features
 Service Strategy
 This Book
 Contents
 To test the multiple-clock state acquisition
 Troubleshooting
 Theory of Operation
 General Information
 Accessories Supplied Agilent Part Number
Accessories
 Characteristics
Specifications
Full Channel
Channel Count
 Probes
 Dimensions
 Equipment Required
Recommended Test Equipment
 Preparing for Use
 To inspect the logic analyzer
Power Requirements
 To connect the 1690A,AD-series logic analyzer to a host PC
To apply power
 To start the user interface
To clean the logic analyzer
To test the logic analyzer
 Testing Performance
 Test Interval
 Materials Required Description
To make the test connectors
Qty
 To make the test connectors
 Set up the test equipment
To set up the test equipment and the logic analyzer
Equipment Required Critical Specifications
Pulse Generator Setup Timebase Channel Trigger
 Oscilloscope Setup Acquisition Display Trigger Shift ∆ Time
Set up the 1680A,AD-series logic analyzer
Channel Define meas
 To perform the logic analyzer self-tests
Set up the 1690A,AD-series logic analyzer
 Set the reporting level
 Click Close to close the Analysis System Self Tests dialog
 To test the threshold accuracy
Set up the equipment
 Connect and configure the logic analyzer
 Test the ECL Threshold
 Test the 0 V User Threshold
 Test the next pod
 To set up the logic analyzer for the state mode tests
 To set up the logic analyzer for the state mode tests
 Click OK to close the Value dialog
 To set up the logic analyzer for the state mode tests
 To test the single-clock, single-edge, state acquisition
 Channel 1 Output
Combinations Channel 2 Output
 Combination Channel 2 Output
 Verify the test signal
 Setup/Hold Combinations Test Sample Position Times Window
Check the setup/hold combination
 To test the single-clock, single-edge, state acquisition
 Following clock configurations will be used in steps 4, 5,
 To test the single-clock, single-edge, state acquisition
 Following clock configurations will be used in steps 9, 10
 To test the single-clock, single-edge, state acquisition
 Test the next channels 1680/81A,AD and 1690/91A,AD
 To test the multiple-clock state acquisition
 1680A, AD or 1690A, AD only
 1682A, AD or 1692A, AD only
 Verify the test signal
 2.0 ns 4.50 ns +3.0 ns
 To test the multiple-clock state acquisition
 To test the multiple-clock state acquisition
 Enable the pulse generator channel 1 Comp with the LED on
 Test the next channels 1680/81A, AD and 1690/91A, AD
 To test the single-clock, multiple-edge, state acquisition
Modify the following pulse generator settings
 1680A,AD or 1690A,AD only Pod 2, channel
 1682A,AD or 1692A,AD only Pod 1, channel
 Verify the test signal
 Check the setup/hold with single clock, multiple clock edges
 To test the single-clock, multiple-edge, state acquisition
 Following clock configurations will be used in steps 3, 4,
 To test the single-clock, multiple-edge, state acquisition
 Test the next channels 1680/81A,AD and 1690/91A,AD
 To test the time interval accuracy
 Function Generator Setup
 To test the time interval accuracy
 Click the Run icon to fill acquisition memory
Acquire and verify the test data
 To test the time interval accuracy
 Performance Test Record
Test Settings Results Self-Tests
Threshold
Accuracy
 Edge Acquisition
Performance Test Record Settings Results
Multiple-Clock Multiple-Edge Acquisition
 Time Interval
Performance Test Record Settings Results Single-Clock
 Performance Test Record
 Calibrating and Adjusting
 Logic analyzer calibration
 Troubleshooting
 To install the fan guard
 To use the flowcharts
 Start
Troubleshooting the Agilent 1680A,AD-series
 Replace Power supply
 Are both instrument
 Yes Possible problem with LCD display, inverter, or cables
 Does the blue
 Uninstall, then reinstall Agilent Logic Analyzer application
 Possible problem with
 To test the power supply voltages
To check the power-up tests
 Pin Voltage
Power Supply Voltages
 To test the LCD display signals
 To test disk drive voltages
Equipment Required Critical Specification
 Disk Drive Voltages Pin No Signal
 To verify the CD-ROM
Disk Drive Voltages Pin Signals Pin No
 To reinstall the operating system
To recover the operating system
 Problems with the Operating System
 Troubleshooting the Agilent 1690A,AD-series
 Yes Is the power cord Connected?
 Consult host PC
 Test pass?
 Task Manager
To verify connectivity
 100
Device Manager
 101
 102
 To run the self-tests
General Troubleshooting
103
 104
 105
 106
Acquisition board status LEDs
 107
To test the logic analyzer probe cables
 108
 109
 110
To check the BNC Trigger input/output signals
 111
On the DC source, enter a voltage setting of 3.000
 Digital Multimeter
To test the auxiliary power
005% accuracy
112
 113
Replacing Assemblies
 Prepare the instrument for disassembly
1680A,AD-series disassembly/assembly
To remove the chassis from the sleeve
114
 115
To remove the acquisition board
 116
 117
To remove the power supply
 118
To remove the hard disk drive
 119
To remove the CD-ROM drive assembly
 120
To remove the flexible disk drive
 121
 122
To remove the PCI boards
 123
To remove the motherboard
 124
Transfer the I/O panel to the replacement board
 125
 126
To remove the front panel assembly
 127
Reverse this procedure to install the front panel assembly
 128
To disassemble the front panel assembly
 129
To remove the distribution board
 130
To remove the inverter board
 131
To remove the fans
 132
To remove the cable tray
 133
1690A,AD-series disassembly/assembly
 134
To remove the fascia
 135
Remove the fascia away from the front panel
 136
 137
To remove the deck
 138
 139
 140
To remove the line filter
 141
To remove the front panel and front frame
 142
 143
Replaceable Parts
 144
Replaceable Parts Ordering
 See Also
Replaceable Parts List
145
 Exploded View
 Replaceable Parts Ref. Des
Agilent 1680A,AD-Series Replaceable Parts
Exchange Assemblies
147
 148
0515-0372
 149
 150
 151
Front Panel Assembly
 152
 Exploded View
 154
Agilent 1690A,AD-Series Replaceable Parts
 155
 156
 157
Power Cables and Plug Configurations
 Plug Type Cable Plug Description Length Color Country In/cm
158
 159
Theory of Operation
 Block-Level Theory
Agilent 1680A,AD-Series Logic Analyzer Block Diagram 160
 161
Agilent 1680A,AD-series Logic Analyzer Theory
 Logic Acquisition Board Block Diagram
Power Supply
Acquisition Board
162
 163
 164
 Front Panel Board
Power Distribution Board
165
 166
Agilent 1690A,AD-series Logic Analyzer Theory
 Self-Tests Descriptions
Power-up Self-Tests 1680A,AD-series
Connectivity Tests 1690A,AD-series
167
 168
Acquisition Board Self Tests
 169
Logic Analyzer Self-Tests
 170
 171
 172
 Manual Part Number Technology Licenses