Chapter 4, Description of Fields

Fields

AFGen2 To

This field has two fields:

the upper field sets the destination port for Audio Frequency Generator 2

FM -RF Generator FM modulator

AM -RF Generator AM modulator

Audio Out -AUDIO OUT connector on front panel of Test Set

the lower field sets the:

FM modulation deviation if the upper field set to FM

AM modulation depth if the upper field set to AM

amplitude of audio signal (volts RMS) at the AUDIO OUT connector if upper field is set to Audio Out

For testing mobile stations, the upper field is normally set to FM, and the lower field set to the desired FM deviation in kHz.

The output level is the peak value for each tone pair, regardless of the Twist and Pre-Empsettings.

Operating Considerations

This is a priority control field. Accessing the RX TEST or TX TEST screen overrides any changes made to this field in other screens.

Screens Where Field is Present

RF GENERATOR

RX TEST