Chapter 4, Description of Fields

Fields

MS Database

This field displays information obtained from the mobile station during registration. Depending on the settings of the Protocol field and the RF Channel Std field, some combination of the following modes are available, with ESN as the default displayed parameter.

ESN - Electronic Serial Number, a permanent, physical attribute of the mobile station.

MCC - Mobile Country Code - displayed when IS-95A or J-STD-008 is selected in the "Protocol" field on page 346.

MNC - Mobile Network Code - displayed when IS-95A or J-STD-008 is selected in the "Protocol" field on page 346.

MSIN - Mobile Station Identification Number - displayed when IS-95A or J-STD-008 is selected in the "Protocol" field on page 346.

MIN1 - Part of the Mobile IdeNtification number, a permanent NAM value - displayed when IS-95 is selected in the "Protocol" field on page 346.

MIN2 - Part of the Mobile IdeNtification number, a permanent NAM value - displayed

when IS-95 is selected in the "Protocol" field on page 346.

Phone Num - The 10-digit directory telephone number.

Dual Mode - Part of the mobile stations’ SCM, a permanent, physical attribute of the mobile station.

Slot Class -Part of the mobile stations’ SCM, a permanent, physical attribute of the mobile station

Pwr Class - Part of the mobile stations’ SCM, a permanent, physical attribute of the mobile station

Tx Mode - Part of the mobile stations’ SCM, a permanent, physical attribute of the mobile station

C Max EIRP - Cellular (BAND_CLASS 0, 2, or 3) MAX_EIRP (Maximum Effective Isotropic Radiated Power) expressed in dBW (MAX_EIRP +60 dBW). Values range from 0 to 255. Displayed when TIA/EIA-95B is selected in the "Protocol" field on page 346.

P Max EIRP - PCS (BAND_CLASS 1 or 4) MAX_EIRP (Maximum Effective Isotropic Radiated Power) expressed in dBW (MAX_EIRP +60 dBW). Displayed when TIA/EIA-95B is selected in the "Protocol" field on page 346.

C Op Modes- Cellular (BAND_CLASS 0, 2, or 3) OP_MODE_INFO. Bits that are set are displayed in MS Database as comma-separated numeric character string (e.g. If OP_MODE0 and OP_MODE1 are set, the displayed string will be 0,1). Displayed when TIA/EIA-95B is selected in the "Protocol" field on page 346.

P Op Modes- PCS (band class 1 or 4) OP_MODE_INFO. Bits that are set are displayed in MS Database as comma-separated numeric character string (e.g. If OP_MODE0 and OP_MODE1 are set, the displayed string will be 0,1). Displayed when TIA/EIA-95B is selected in the "Protocol" field on page 346.