Chapter 4, Description of Fields

Fields

Operating Considerations

The report interval is specified in terms of error count or frame count.

See Also

by # errors field description, on page 187 by # frames field description, on page 188

MS FER Report Interval field description, on page 308

Screens Where Field is Present

CDMA MOBILE REPORTED FER

Errors Counted

This field displays the number of frame errors counted during or after an FER test. A Service Option 2 (mobile station data loopback) call must be connected before running an FER test.

GPIB Example

“DISP CRXT;MEASure:CDManalyzer:FERasure:ERRors?“

queries the FER errors measurement result.

Operating Considerations

A measurement result will be displayed at the end of a test if Display Interim

Results is No. Measurement results will be displayed continuously if Display

Interim Results is Yes.

Screens Where Field is Present

CDMA CELLULAR MOBILE RECEIVER TEST