Chapter 4, Description of Fields

Fields

Pilot Inc

This field allows entry of the increment between the pilot PN offsets of the

Neighbor Set pilots.

When a mobile station finds CDMA service from the Test Set it is assigned seven Neighbor Set pilots in the Neighbor List Message. The Test Set assigns the first Neighbor Set pilot to the same PN offset as Sector B (this value is displayed on the CDMA Generator Control screen).

To complete the list, six additional Neighbor Set pilots are assigned equally- spaced PN Offsets, beginning with 15 times the Pilot Inc field setting. For example, if Pilot Inc is set to 10, the entire Neighbor Set would consist of the following pilots: 150, 160, 170, 180, 190, and 200. All values will be congruent to modulo 512, which is the number of unique values allowed for the pilot offset index.

GPIB Example

“DISP CCON;CDMA:CELL:CONFigure:PINcrement 12“

sets the Pilot Inc field to 12.

Operating Considerations

This field affects the range of PN Offsets over which the mobile station has to search to monitor power levels of pilots in the Neighbor list

Range of values: 1 through 15

Screens Where Field is Present

CDMA CELL SITE CONFIGURATION

334

S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp

Page 334
Image 334
Agilent Technologies E8285A manual Sets the Pilot Inc field to