Agilent Technologies E8285A manual MS FER Report Interval, Ms Id

Models: E8285A

1 464
Download 464 pages 57.8 Kb
Page 308
Image 308

Chapter 4, Description of Fields

Fields

MS FER Report Interval

This field sets the number of frames the mobile station will count before reporting frame error rate (FER) when the by # frames field is On.

GPIB Example

“DISP CFER;CDMA:MOBile:FERasure:REPort:INTerval’160 FRAMES’“

sets the mobile station’s FER report interval to 160 frames.

Operating Considerations

This setting may affect FER measurement speed and will affect the display rate of the MS FER Report field.

Screens Where Field is Present

CDMA MOBILE REPORTED FER

MS ID

The MS ID field determines how the Test Set identifies a mobile station for paging. Depending on the Protocol field choice, some combination of the following modes are available, with Auto as the default.

Auto - The Test Set will obtain the mobile station’s identification through mobile station registration, either at mobile station power-on or when the Register field is selected.

Phone Num -Allows entry of a 10-digit phone number that identifies the mobile station, overriding any value for phone number that the test set may have obtained during mobile station power-on registration. The mobile station must be NON- SLOTTED to use this MS ID mode. This choice is displayed when IS-95 is selected in the "Protocol" field on page 346.

MIN - Allows entry of MIN, a 9-digit hexadecimal string normally derived from the phone number, overriding any value for MIN that the test set may have obtained during mobile station power-up registration. The mobile station must be NON-SLOTTED to use this MS ID mode. This choice is displayed when IS-95 is selected in the "Protocol" field on page 346.

IMSI - Allows entry of IMSI, consisting of MCC, MNC, and MSIN. This choice is displayed when IS-95A, TSB-74, KorPCS, ARIB T53, or J-STD-008 is selected in the "Protocol" field on page 346.

308

S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp

Page 308
Image 308