Agilent Technologies E8285A manual Srch Win a, Sets search-window a to

Models: E8285A

1 464
Download 464 pages 57.8 Kb
Page 404
Image 404

Chapter 4, Description of Fields

Fields

Srch Win A

This field allows entry of the search-window size for the active set and candidate set.

GPIB Example

“DISP CCON;CDMA:CELL:CONFigure:AWIN 5“

sets search-window A to 5.

Operating Considerations

The mobile station searches for the strongest pilot channel signal and usable multipath components of the pilot channel signals included in the active and candidate sets. The search-window limits the range of PN sequence offsets that the mobile station searches.

The range of values for the searcher window size is 0 to 15.

0 = 4 PN chips (minimum)

5 = 20 PN chips (default)

15 = 452 PN chips (maximum)