Chapter 2, Description of Connectors

Connectors

AUDIO IN LOW, HIGH

The audio inputs are used to input audio signals to the AF Analyzer.

AUDIO IN HI is the main audio signal input connection.

AUDIO IN LO is used for the audio signal reference. Three choices are available using

the AF ANALYZER screen'sAudio In Lo field:

Gnd - connects the center pin through approximately 100 Ω to chassis ground

Float - provides a floating input.

600 To Hi - provides a 600 ohm internal load to match an audio source with an out- put.

The measured level is the potential between the HIGH and LOW center pins. The shells of both connectors are at chassis ground.

Operating Considerations

BNC

Input impedance switchable between

1 M Ω in parallel with 95 pF,

600 Ω floating.

This port is selected as the AF Analyzer's input using the AF Anl In field in the analog TX TEST screen, DUPLEX TEST screen, and AF ANALYZER screen. This port is always the AF Analyzer's input when the analog RX TEST screen is displayed.

Signals input to the AF Analyzer are routed through different filters, amplifiers, and detectors that affect the displayed measurement.

CAUTION:The maximum level between the HI and LO center pins is 42 V peak (approximately 30 Vrms). Exceeding this value can cause permanent instrument damage.

See Also

AF Anl In field description, on page 155

Audio In Lo field description, on page 169