Agilent Technologies E8285A TDrop, This field allows entry of the pilot drop threshold Tdrop

Models: E8285A

1 464
Download 464 pages 57.8 Kb
Page 421
Image 421

Chapter 4, Description of Fields

Fields

T_Drop

This field allows entry of the pilot drop threshold (T_DROP).

GPIB Example

“DISP CMOB;CDMA:MOBile:TDR 40“

sets T_DROP to 40.

Operating Considerations

When the Softer Handoff annunciator is lit, Sector A and Sector B are added to the mobile station’s Active list. If either of these pilot’s signal strength falls below T_DROP, the mobile station starts its handoff drop timer, T_TDROP. If the weaker pilot’s signal strength remains below T_DROP and the timer expires, the mobile station will send a Pilot Strength Measurement message to the Test Set. The Test Set will display “To Drop” in the Status column of the CDMA Mobile Reporting table for the Sector A or Sector B pilot that fell below T_Drop (identified by PN Offsets).

See Also

T_TDrop field description, on page 422

Screens Where Field is Present

CDMA MOBILE REPORTED PILOT STRENGTH