Chapter 4, Description of Fields

Fields

NOTE:Decoder and Oscilloscope Interference: The AF autoranging function (Auto) takes a small amount of time to determine the attenuation settings for the AF Analyzer. If you are decoding an encoded signal, and your transmitter begins sending encoded information the instant it transmits, the initial encoded information may not be decoded during the autoranging process.

Use the Auto setting to establish the initial gain settings while the encoded signal is first being decoded, and then select Hold during the decoding process to retain the gain settings. The decoder should capture all encoded information the next time you transmit the signal.

Screens Where Field is Present

AF ANALYZER

(Gen)-(Anl)

This field is used with the RF Offset field to specify the amount of frequency offset between the RF Generator and RF Analyzer.

This field is not displayed when the RF Display field is set to Chan (the offset is automatically set when using channel tuning).

Screens Where Field is Present

CONFIGURE

Grid

This field is displayed only when Display is selected in the Controls field.

This field provides control of the CDMA GATED POWER display grid.

On displays dashed lines delineating the time scale on the X axis and the relative level scale on the Y axis. .

Off erases the dashed lines, leaving only the mask and measurement trace information.

GPIB Example

“DISP CGP;CDMA:GPOWer:GRID ’On’“

turns off the display grid.

Screens Where Field is Present

CDMA GATED POWER