Agilent Technologies E8285A manual Esc Mode, ESN dec, Enables escape mode

Models: E8285A

1 464
Download 464 pages 57.8 Kb
Page 248
Image 248

Chapter 4, Description of Fields

Fields

Esc Mode

This field is displayed when the field called "Protocol" on page 346 has IS-95A, TSB-74, or J-STD-008 selected.

This field, when set to “On”, configures the Test Set as a base station that is compatible with any Country Code/Network Code combination that a mobile station is programmed with.

On (enables escape mode)

Off (disables escape mode)

GPIB Example

“CDMA:CELL:CONF:EMOD ‘On’”

enables escape mode.

Operating Considerations

When Escape Mode is “On”, the Cntry Code and Netwrk Code fields are no longer needed and are removed from the Cell Site Configuration screen. The mobile station may still require a specific Network ID and System ID setting to find service from the Test Set.

See Also

Protocol field description, on page 346

Screens Where Field is Present

CDMA CELL SITE CONFIGURATION

ESN (dec):

This field displays the electronic serial number (ESN), in decimal form, received from the mobile station on the reverse control channel in response to a forward control channel message. The ESN (dec): field is displayed only when the Display field is set to Data and a reverse control channel message containing this information has been decoded.

Refer to the "Display" field on page 223 for information on how to read measurement results from this field.

Screens Where Field is Present

CALL CONTROL

248

S:\agilent\e8285\REFGUIDE\MANUAL\fields.chp

Page 248
Image 248