Agilent Technologies E8285A manual Key Digits, Enters a 1 preceded by 19 0’s in the A-Key field

Models: E8285A

1 464
Download 464 pages 57.8 Kb
Page 161
Image 161

Chapter 4, Description of Fields

Fields

Example

OUTPUT 714;"CALLP:AMPS:AUTH:AKEY:GEN"

OUTPUT 714;"CALLP:AMPS:AUTH:AKEY?"

ENTER 714;Akey_val$

Screens Where Field is Present

AUTHENTICATION

A-Key Digits

This field is used to enter the decimal digits used to generate the A_Key. When a number is entered, the Test Set will add leading zeroes if necessary to fill the field with 20 digits. The default setting is all zeroes.

GPIB Example

“CDMA:AUTH:AKEY ‘1’”

enters a 1 preceded by 19 0’s in the A-Key field.

Operating Considerations

When a new value for A_Key is entered into the A_Key field, the Test Set’s

Shared Secret Data (SSD_A) is initialized to zero.

Check Digits are computed and displayed if a valid ESN is present in the MS

Database when a number is entered in the A_Key field.

NOTE:

Check Digits are not affected by ESN when Kor PCS is selected in the Protocol field.

 

 

 

See Also

"SSD Update (annunciator)" field on page 410 "Check Digits" field on page 200