Chapter 4, Description of Fields

Fields

Operating Considerations for Status Field

When a call is made, the mobile station’s Active list is initialized to contain only Sector A. When Sector B’s signal strength exceeds the threshold determined by the entry in the T_Add field, the mobile station will send a Pilot Strength Measurement Message to the Test Set. The Test Set will then display “Candidate” under the Status column for Sector B (Sector A and Sector B are identified by their PN Offsets).

If the power level of Sector B exceeds Sector A power by more than T_Comp*0.5 dB, the mobile station will send another Pilot Strength Measurement Message, and the Sector B status will change to “To Add”, meaning that Sector B has sufficient signal strength to be added to the mobile station’s Active List.

When a softer handoff has begun, the Test Set will send a Handoff Direction Message to the mobile station, adding Sector B to the mobile station’s active set. The mobile station will then perform diversity combining of Sector A and Sector B. When the next Pilot Strength Measurement Message is sent from the mobile station, Sector A and Sector B Status will either be “Active” or “To Drop”. If an “Active” pilot’s signal strength is decreased to a level determined by the other Sector power and the entry in the T_Drop field, the status column will change to indicate “To Drop” status. Conversely, if a “To Drop” pilot’signal strength is increased to a level determined by the other Sector power and the entry in the T_Comp field, the status column will change to indicate “Active” status

See Also

Srch Win A field description, on page 404

Srch Win N field description, on page 405

Srch Win R field description, on page 406

Screens Where Field is Present

CDMA MOBILE REPORTED PILOT STRENGTH