Diagnostic Testing Sequence

 

 

where:

 

slot

Specifies which card cage slot to test. The diagnostic software

 

determines the type of card in the slot and downloads the

 

appropriate tests.

halt

(Optional) Stops the active diagnostic test.

previous

(Optional) Allows you to examine the last test results on the card,

 

stored in EEPROM, specified by the slot parameter.

mbus1

(Optional) Forces the route processor to load diags from the

 

mbus.

verbose

(Optional) Turns on the status messaging capability of the

 

diagnostics. The default is minimum messaging.

wait

(Optional) Stops the diagnostics from reloading the Cisco IOS

 

image following the completion of diagnostic testing. The card

 

must be ejected from the slot, reinstalled in the slot, and

 

reconfigured manually.

coe2

(Optional) Continues testing even after a failed test.

(Continue on error)

 

1.Using this option results in a 15-minute delay before test results are returned. This command option is available when using Cisco IOS Release 12.0(21)S or 12.0(21)ST, or a later release of 12.0S or 12.0ST.

2.Not recommended for use on operational, business-critical routers. This command option is available when using Cisco IOS Release 12.0(21)S or 12.0(21)ST, or a later release of 12.0S or 12.0ST.

To stop diagnostic testing at any time, enter the halt option in the command, at the privileged EXEC mode prompt on the system console:

diag slot halt

Diagnostic Testing Sequence

When testing a card, the diagnostics perform the following operations in this sequence:

1Halts the normal operation of the card.

The card is no longer available for network traffic.

Running Diagnostics on the Cisco 12008 6-3