Loading and Running Diagnostics

Failed Diagnostic

If a diagnostic test fails on a line card, testing halts with that test. The line card will not reload or come back online automatically. The following example shows a diagnostic message stream to the console for a line card located in slot 7. In the example, the card fails one of the diagnostic tests, stopping the diagnostic cycle on that test.

Router# diag 7 verbose

Running DIAG config check

Running Diags will halt ALL activity on the requested slot. [confirm]

Router# <Return>

Launching a Field Diagnostic for slot 7

Downloading diagnostic tests to slot 7 (timeout set to 400 sec.)

Field Diag download COMPLETE for slot 7

FD 7> ****************************************************

FD 7> GSR Field Diagnostics V3.0

FD 7> Compiled by award on Tue Aug 3 15:58:13 PDT 2000

FD 7> view: award-bfr_112.FieldDiagRelease

FD 7> ****************************************************

FD 7> BFR_CARD_TYPE_OC48_1P_POS testing...

FD 7> running in slot 7 (128 tests)

Executing all diagnostic tests in slot 7 (total/indiv. timeout set to 600/220 sec.) FD 7> Verbosity now (0x00000001) TESTSDISP

FDIAG_STAT_IN_PROGRESS: test #1 R5K Internal Cache

FDIAG_STAT_IN_PROGRESS: test #2 Burst Operations

FDIAG_STAT_IN_PROGRESS: test #3 Subblock Ordering

.

.

.

FDIAG_STAT_IN_PROGRESS: test #21, error_code 5

Field Diagnostic: ****TEST FAILURE**** slot 7: last test run 21,

To Fabric SOP FIFO SRAM Memory, error 5

Field Diag eeprom values:run 0 fail mode 1 (TEST FAILURE) slot 7 last test failed was 21, error code 5

Shutting down diags in slot 7

slot 7 done, will not reload automatically

Router#